1. INITIAL SETTINGS AND ADJUSTMENTS
1-12
are connected to the same network, change the IP address of the RCB-002s, re-
ferring to "SUBSYSTEM" on page AP-3.
• [RCB00u (Main)] (u: 1 to 4): Input the location information of the external radar
antenna that is connected to the [RADAR SIGNAL IN No.1] port.
• [RCB00u (Sub)] (u: 1 to 4): Input the location information of the external radar
antenna that is connected to the [RADAR SIGNAL IN No.2] port. Set parame-
ters for the [RCB00u (Main)] before setting parameters for the [RCB00u (Sub)].
7. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.
1.4 [Installation Parameters] Menu
The [Installation Parameters] menu sets the signals and input data of the sensors.
First, select the sensor data at the [Sensor Setting] window. Then select the sensor
from which the units (radar sensor (antenna unit), MFD, ECDIS, radar, and sensor
adapter) obtain the sensor data.
1.4.1 Sensor setting
1. Access the [Common Installation Setting] menu and click [Installation Parame-
ters] on the tab bar.
2. Click [Sensor Setting] on the menu bar, then click [GPS Sensor].
3. Check applicable check boxes according to the number of GPS receivers con-
nected.
4. Set the following items for the units activated at step 3.
The time to timeout for receiving
data. Keep the default setting.
The time to timeout for receiving
data. Keep the default setting.