1. INITIAL SETTINGS AND ADJUSTMENTS
1-38
4. Select [Alert Transfer Setting] and [Backup Navigator Setting] on the menu bar.
5. Set the following items.
6. Select [VDR Setting] on the menu bar.
7. Set the following items.
8. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.
[Output 01(02)] Select Equipment ID of the destination equipment to transfer the
alert data. A maximum of two equipments can be assigned to the
destination.
[ ] button
Opens the [Alert No.Setting] di-
alog box to register the alert to
the group. Select the alert
source equipment from the
[Equipment ID] pull-down list.
Activate the radio button of the
appropriate alert(s), then [OK]
button to register the alert. The
right figure is the example when
alert notification sentence is
ALF. The alert notification sen-
tence is dependent on the specification of the equipment con-
nected to this ECDIS. After clicking the [OK] button, Equipment
ID, alert no. and alert description appear in the alert registration
field.
Item Remarks
[Transfer Alerts] Select [YES] to transfer the alert to the backup navigator equip-
ment when an alarm is not acknowledged for 30 seconds.
[Output] Select the backup navigator equipment to be used for alert data
transfer.
[Anschutz AP] Not used.
[Alert No.]
Item Remarks
[Transfer Alerts] Select [YES] to transfer the alert to VDR.
[Output] Select the VDR to be used for alert data transfer.
Item Remarks