– 19 –
Installation information is for reference only. See the 
Installation Instructions shipped with the product for 
complete details and before attempting to install the 
range or rangetop.
Caution: These ranges weigh up to 700 pounds. 
Some disassembly will reduce the weight 
considerably. Rangetops weigh up to 170 pounds. 
Due to the weight and size of the range or rangetop, 
and to reduce the risk of personal injury or damage 
to the product:
TWO PEOPLE ARE REQUIRED FOR PROPER • 
INSTALLATION OF 36" AND 30" RANGES AND 36" 
AND 48" RANGETOPS.
THREE PEOPLE ARE REQUIRED FOR PROPER • 
INSTALLATION OF 48" RANGES.
Gas Supply Range and Rangetop
The natural gas models are designed to operate at 
5" water column pressure. For proper operation, the 
pressure of the natural gas supplied to the regulator 
must be between 7" and 13" water column.
The LP models are designed to operate at 10" water 
column pressure. For proper operation, the pressure 
of the LP gas supplied to the regulator must be 
between 11" and 13" water column.
All models can be ordered to operate on NATURAL 
or LP gas. Models ordered to operate on NATURAL 
gas are shipped with an LP conversion kit. Models 
ordered to operate on LP gas are shipped with a 
NATURAL gas conversion kit.  
High Altitude Conversion Kit - For operation 
above 6,000 feet, order Part #WB28K10553. This 
kit includes orifi ces for both LP and Natural gas 
operation. 
A manual shut-off valve in the gas line (not 
provided), is to be installed in an easily accessible 
location. Make sure the homeowner knows where 
and how to shut off the gas supply to the range or 
rangetop.
Installation 
Range Electric Supply
These ranges must be supplied with 208/240 volt, 
60 Hz., and connected to an individual, properly 
grounded branch circuit. 
This branch circuit is to be protected by a circuit 
breaker or time delay fuse (50 amp for 48" ranges, 
30 amp for 36" and 30" ranges). 
The receptacle must be a NEMA 14-50R device to 
accept the 4-prong plug supplied with the range.
If the electrical service provided does not meet 
the above specifi cations, it is recommended that a 
licensed electrician install an approved outlet.
Rangetop Electric Supply 
These rangetops must be supplied with 120 volt, 
60 Hz., and connected to a dedicated, properly 
grounded branch circuit protected by a 15 amp 
circuit breaker or time delay fuse.
The power cord of this appliance is equipped with 
a three-prong (grounding) plug which mates with a 
standard three-prong grounding wall receptacle to 
minimize the possibility of shock hazard from this 
appliance.
If the electrical service provided does not meet 
the above specifi cations, it is recommended that a 
licensed electrician install an approved outlet.
Backsplash Requirements
All models require 12" minimum clearance to a 
vertical combustible surface at the rear. In a range 
installation, if clearance is less than 12", the entire 
surface of the back wall above and the full width 
of the range must be protected by a backsplash. 
In a rangetop installation, if clearance is less than 
12", the entire surface of the back wall above the 
countertop and the full width of the rangetop must 
be protected by a backsplash. The backsplash must 
be constructed of non-combustible material, such 
as metal, ceramic tile, brick, marble or other stone.
WARNING: Installations without a hood require 
48" minimum to combustibles. A custom hood 
installation with exposed horizontal combustible 
surfaces must have an Auto-On feature. Refer to 
hood installation instructions for specifi c hood 
clearances.