03-10= 0 0 0 0 0: normally open switch
s8 s7 s6 s5 1: normally close switch
Example: S1 and S2 wired to a normally closed contact / switch set 03-09=0011.
Do not set the operation command parameter 00-02 to terminal control before setting the digital input type.
Failure to comply may cause death or serious injury.
Nepasréglerleparamètredecommandedufonctionnement00-02surlacommandeduterminalavantd’avoir
conguréletyped’entréenumérique.Lenon-respectdecetteprescriptionpeutentraînerdesblessuresgraves,
voirefatales.
Code Parameter Name / Range
03-11 Relay (R1A-R1C) output
03-12 Relay (R2A-R2C) output
0: During Running
1: Fault contact output
2: Frequency Agree
3: Setting Frequency Agree (03-13 ± 03-14)
4: Frequency detection 1 (> 03-13, hysteresis range is the setting value of 03-14)
5: Frequency detection 2 (< 03-13, hysteresis range is the setting value of 03-14)
6: Automatic restart
7~8: Reserved
9: Baseblock
10~11: Reserved
12: Over-Torque Detection
13: Current Agree
14: Mechanical Braking Control (03-17~18)
15~17: Reserved
18: PLC status
19: PLC control contact
20: zero speed
21: Inverter Ready
22: Undervoltage Detected
23: Source of operation command
24: Source of frequency command
25: Low torque detected
26: Frequency reference missing
27: Time function output
28: Traverse operation UP status
29: During Traverse operation status
30: Motor 2 selection
31: Zero Speed Servo Status (Position Mode)
32: Communication control contacts
33~36: Reserved
37: PID feedback loss detection output
38: Brake release
39: Frequency Detection 1 (dedicated for Crane)
40: Frequency Output
41: Position Agree (Position Mode)
42: Reserved
43: Reserved
44: Reserved
45: PID sleep
46: Reserved
47: Reserved
48: Reserved
49: Reserved
50: Frequency Detection 3 (> 03-44+03-45)
51: Frequency Detection 4 (< 03-44+03-45)
52: Frequency Detection 5 (> 03-46+03-47)
53: Frequency Detection 6 (< 03-46+03-47)
54: Turn on short-circuit braking
Caution
VDI100 • Instruction manual 155