Function Detection operation of frequency confirmation Description
Output frequency
detection 2
OFF OFFON ON
03-14
03-14
03-13
03-13
03-13
03-13
time
time
Output
Frequency
Output
Frequency
Detection 2
Signal
ON
Output is active when the output frequency is below the frequency
detection level (03-13) + frequency detection width (03-14) and
turns off when the output frequency falls below frequency detection
level.
Any of the digital outputs function (03-11, 03-12 or 03-28) can be
set to 5 (Output frequency detection 2).
Output frequency
detection 3
ON ONOFF OFF
03-45
03-45
03-44
03-44
03-44
03-44
time
time
Output
Frequency
Output
Frequency
Detection 1
Signal
Output is active when the output frequency rises above the frequen-
cy detection level 2(03-44) + frequency detection width 2(03-45)
and deactivates when the output frequency falls below frequency
detection level 2(03-44).
Any of the digital outputs function (03-11, 03-12 or 03-28) can be
set to 50 (Output frequency detection 3).
Output frequency
detection 4
ON ONOFF OFF
03-45
03-45
03-44
03-44
03-44
03-44
time
time
Output
Frequency
Output
Frequency
Detection 1
Signal
Output is active when the output frequency is below the frequency
detection level 2(03-44) + frequency detection width 2(03-45) and
turns off when the output frequency falls below frequency detection
level 2(03-44).
Any of the digital outputs function (03-11, 03-12 or 03-28) can be
set to 51 (Output frequency detection 4).
Output frequency
detection 5
ON ONOFF OFF
03-47
03-47
03-46
03-46
03-47
03-46
time
time
Output
Frequency
Output
Frequency
Detection 1
Signal
Output is active when the output frequency rises above the frequen-
cy detection level 3(03-46) + frequency detection width 3(03-47)
and deactivates when the output frequency falls below frequency
detection level 3(3-46).
Any of the digital outputs function (03-11, 03-12 or 03-28) can be
set to 52 (Output frequency detection 5).
Output frequency
detection 6
OFF OFFON ON
03-47
03-47
03-46
03-46
03-46
03-46
time
time
Output
Frequency
Output
Frequency
Detection 2
Signal
ON
Output is active when the output frequency is below the frequency
detection level 3(03-46) + frequency detection width 3(03-47) and
turns off when the output frequency falls below frequency detection
level 3(03-46).
Any of the digital outputs function (03-11, 03-12 or 03-28) can be
set to 53 (Output frequency detection 6).
VDI100 • Instruction manual 161