- 14 -
Spark plug without flashover
Fault Diagnosis Adjustment Check Fault Cause
The spark plug
jump weak or
no fire jump
Hot spark
Replace new spark
p
lu
g
s to chec
k
Without sag With sag
Check the spark
p
lu
g
check a
g
ain
Normal Abnormal
Examination of each terminal wire
plug CDI between conduction,
resistance value measurement
Normal Abnormal
Abnormal Normal
Related parts
inspection
Check whether the plug
CDI
g
rou
p
flabb
y
Normal
Abnormal
Use the test CDI
i
g
nition coil chec
k
Use the check CDI
group CDI test
Abnormal
Spark plug the bad
Spark plug cover relaxation
Plug contact undesirable
The Lord switch bad
Charging coil bad
Trigger bad
Ignition coil badly
The Lord wiring broken
Joint socket contact undesirable
Unhealthy CDI group
Unhealthy ignition coil

Table of Contents