- 23 -
Voltmeter shall be used for charging
inspection.
Charging
Connection method: Positive pole of battery charger is connected to battery positive lead wire;
Negative pole of battery charger is connected to battery negative lead wire.
Warning!
• Battery shall be away from fire.
• Shut off charger switch first before or
after charging in case sparks may be
generated at connection parts, which may
result in explosion.
• During charging, please take the
current time labeled on the battery as
basic time.
* Attention
• Battery quick recharging is not
recommended except in case of
emergency.
• After recharging, wait at least
30minutes and then measure the battery
voltage.
Recharging current: Standard: 0.4A
Quick recharging: 4.0A
Recharging time: Standard: 10-15hours
Quick recharging: 30minutes
After recharging: Closed circuit voltage: over 12.8V
Restrictor
Idle speed adjustment
*Attention
Perform idle speed adjustment when the
engine is warm.
Warm up the engine and then adjust idle speed.
Run the engine and connect engine tachometer.
Adjust the throttle cable lock-screw to specified RPM.
Idle speed RPM: 1,700±100rpm/min