EasyManua.ls Logo

GF CMD - Probe CMD-4;6 Assembly

GF CMD
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
CMD
Probe CMD4/6
CMD-4/6 probe can be assembled to its maximum length to reach the
effective depth range of 9 meters (CMD-6) or can be used with reduced length
with the effective depth range of 6 meters (CMD-4).
For CMD-4 assembling put three longer parts of the probe to each other
having “T” and “I” marks in one line. Transmitter, which is labeled by I”, is to be
connected on the left side. Receiver, which is labeled by “T”, is to be connected on
the right side. For CMD-6 assembling insert two shorter parts between the longer
ones. Then connect the connector and assemble the arms by turning the bayonet
rings. See pictures below.
If you wish to measure with maximum depth range (HIGH), turn the probe
to position with the black strip and “Hi” label on the upper side. If you wish to
measure with half depth range (LOW), turn the probe to position with the black
strip and “Lo” label on the upper side.
9m depth range
6m depth range
Connector
Belt holder

Table of Contents