Page #10 background image
10
Instruction manual
Electric Actuators Type EA15-250
3 Product description
3.1 Intended use
The EA15/25/45/120/250 electric actuators are designed for mounting on a valve and for connection to a control system provided
by the plant and are intended to operate valves with swivel movements of up to 180° (e.g. ball valves and butterfly valves).
The product is not intended for any other type of use than those listed here. Failure to observe the instructions contained in this
manual will void the manufacturer›s liability for the above-mentioned products. The Actuator is designed for integration into a com-
plete machine/peripheral system. It is not intended for direct connection to a voltage supply system, but only to a regulated and fused
power supply of a complete machine.
3.2 Use not in accordance with the intended use
Any use other than that described in the intended use is not in accordance with the intended use and is therefore not permitted.
If unsuitable products are installed or used in safety-relevant applications, unintended operating conditions may occur in the appli-
cation that can cause personal injury and/or property damage.
Only use the product in safety-relevant applications if this use is expressly specified and permitted in the product documentation.
GF Piping Systems AG accepts no liability for damage resulting from improper use. The risks associated with improper use lie solely
with the user.
3.3 EC Declaration of Incorporation
The manufacturer Georg Fischer Rohrleitungssysteme AG, 8201 Schahausen (Switzerland) declares that the following partly com-
pleted machines according to the listed harmonized type standards are partly completed machines in the sense of the EC Machinery
Directive 2006/42/EC, Annex II B, and that they comply with the requirements of this directive that apply to partly completed machi-
nes. The commissioning of these partly completed machines, as well as their CE marking, is prohibited until the conformity of the
complete installation into which the partly completed machines are built is declared with the mentioned EC directive. Furthermore,
we declare that the special technical documentation was prepared in accordance with Annex VII, Part B of this directive.
Modifications to the products that aect the specified technical data and the intended use make this declaration invalid.
Additional information can be found in the “GF Planning Fundamentals”.
Product group Type designation Additional directives and harmonized design standards
Electric Actuators EA15
EA25
EA45
EA120
EA250
2006/42/EG, Annex II B
2014/35/EU*
2014/30/EU
2011/65/EU
EN 60204-1
EN ISO 12100
EN 60947-1*
EN 61010-1
2008 No. 1597
2016 No. 1101
2016 No. 1091
2012 No. 3032
*valid for 100-230V types
Schahausen, 09.05.2023
Bastian Lübke
Head of Global R&D
Georg Fischer Piping Systems Ltd.
CH-8201 Schahausen (Switzerland)