33
2.4 Reaction of automatic closing to photocell
Use this menu item to stop automatic closing when the
photocell is activated. This requires a photocell connected to
terminals X6 and activation of menu item
2.3.
In operating mode (
0.1) hold-to-run, this menu item has no
e󰀨ect.
2.4
Reaction of automatic closing to photocell
. 0
Deactivated
. 1
Stopping of automatic closing 2.3
The door closes 3 seconds after the interruption of the photocell has ended.
.2
People and vessel recognition
If the interruption of the photocell lasts less than 1.5 seconds (e.g. a person
passesthedoor),thedoorclosesafterthetimespeciedin
2.3.
If the interruption of the photocell lasts longer than 1.5 seconds (e.g. a
vehicle passes the door), the door closes after 3 seconds.
If the light beam is interrupted, fault indication
F 2.1. appears.

Table of Contents