43
8.5/8.6 Setting the maintenance cycle counter
With these menu items, you set a reminder for the
maintenance of the door. The maintenance cycle can be set
between 1,000 and 99,000 cycles. The counter decreases by
1everytimethedoorreachesthenallimitpositionOPEN.
When the counter reaches the value 0, the setting from menu
item
8.6 is activated.
8.5
Setting the maintenance cycle counter
►
.0
Deactivated.
. 1 - 9.9
Activated.
Counting down from
.1 = 1,000 cycles to 9.9 = 99.000 cycles.
8.6
Response after expiry of the maintenance cycle counter
►
. 1
Display shows C.S alternatingwiththevaluespeciedin8.5
.2
Operating mode change to hold-to-run.
Display shows
C.S.alternatingwiththevaluespeciedin8.5.
.3
Operating mode change to hold-to-run.
Display shows
C.S.alternatingwiththevaluespeciedin8.5.
Option: Press the STOP button for 3 seconds to ignore the message for 500
cycles.
.4
Display shows C.S.alternatingwiththevaluespeciedin8.5.
Relay contact X21 switches.
You can delete the response from menu item
8.6 by setting a
new value with menu item
8.5.