44
9.1 Readout of cycle counter
With this menu item, you can read out the cycle counter of the
door control. The counter increases by 1 every time the door
reachesthenallimitpositionOPEN.Itisnotpossibletoreset
the cycle counter.
9.1
Readout of cycle counter
After selecting the menu item, the display changes 7 times to show a 7-digit
number.
The left side of the two-digit display shows a symbol for the current
position of cycle counter.The right side shows the number of the current position.
The example below shows 1,000,000 cycles.
9.2 Readout of fault indications
With this menu item, you can read out the last 6 fault
indications of the door control. After selecting the menu item,
the display changes and shows the last six fault indications.
First an F is shown, then the number of the fault indication. The
rstfaultindicationdisplayedisthemostrecent.
9.2
Readout of the latest fault indications
The display changes and shows the last 6 fault indications.