34
2.5Limitingreversals
Activate this menu item only if automatic closing 2.3 is enabled.
Whenautomaticclosingisenabled,thedoormovestonallimit
position CLOSED after the set time. The door reverses when
hitting an obstacle during movement. This means that the door
changesthedirectionofmovementandmovestothenallimit
position OPEN. Thanks to automatic closing, the door tries to
close again after the set time has elapsed. This will continue until
the obstacle is removed.
To prevent continuous opening and closing in this situation, you
can specify a maximum number of successive reversals. When
thespeciednumberhasbeenreached,thedoorstopsinnal
limit position OPEN.
When the door exceeds the set number of reversals, fault
indication
F 2.2 appears.
2.5
Limitingreversals
.0
Deactivated
. 1 - 1.0
Activated
. 1 = 1 reversal - 1.0 = 10 reversals
►Factory setting .2 = 2 reversals