47
Faults of safety devices
Causes of faults Fault correction
F. AnzeigewechseltzwischenF.undZi󰀨er
2.0
No safety edge detected. Check wiring of the safety edge.
2. 1
Terminals X6 are open.
Photocell activated.
Check alignment of the photocell.
Check connecting cable for interruption.
Replace photocell if necessary.
2.2
Max. number of reverses
(
2.5) reached by
activations of the safety
edge
Remove obstacles from the door area.
MovetonallimitpositionCLOSE.
Check function of the safety edge.
Reset or deactivate menu item 2.5.
2.4
Safety edge 10k2
activated
Check function of the safety edge.
Check connecting cable for short circuit.
2.5
Safety edge 10k2
defective
Check function of the safety edge.
Check connecting cable for interruption.
2.6
Safety edge 1k2
activated.
Check function of the safety edge.
Check pneumatic switch.
Check connecting cable for short circuit.
2.7
Safety edge 1k2
defective.
Check function of the safety edge.
Check connecting cable for interruption.
2.8
Safety edge 1k2 test is
negative
Check pneumatic switch.
Check pre-limit switch.
Check safety edge for damage.
2.9
Optical safety edge is
activated or defective.
Check function of the safety edge.
Check connecting cable for interruption.