58542 VXIbus Universal Power Meter
2-54 Publication 21555, Rev. E, September 2002
SENSe:CORRection:EEPROM:CALFactor?
Syntax:
SENSe<sensor 1 or 2>:CORRection:EEPROM:CALFactor?
Example:
OUTPUT @PWR_MTR;SENS1:CORR:EEPROM:CALF? ! QUERIES SENSOR 1 EEPROM CAL FACTOR TABLE
Response:
Typically, 5.000e7,2.000e9,......
Description:
Provides a listing of calibration factors in the sensor, sorted in frequency order, to match
previous command. The number of items matches the sum of the number at standard
frequencies, and the number of special frequencies reported by
DIAG:SENS1:EEPROM:CALFR?
SENSe:CORRection:EEPROM:FREQuency?
Syntax:
SENSe<sensor 1 or 2>:CORRection:EEPROM:FREQuency?
Example: OUTPUT @PWR_MTR;SENS1:CORR:EEPROM:FREQ? ! QUERIES SENSOR 1 EEPROM FREQUENCY TABLE
Response:
Typically, 5.000e7,2.000e9,......
Description:
Provides a listing of calibration frequencies in the sensor, sorted by frequency, so that both
standard and special frequencies are listed. The number of items matches the sum of the
number at standard frequencies, and the number of special frequencies.