16
the values prescribed� When the appliance is installed under the extraction
hood, check that the following indications are respected:
a) the volume extracted must be higher than that of the ue gases
generated (see current regulation);
b) the material with which the hood lter is made must resist the
temperatureoftheuegaseswhich,onexitingtheconveyor,canreach300°C;
c) the end part of the appliance evacuation pipe must be positioned
inside the base perimeter projection of the hood;
d) the gas supply must be restored manually following a block caused by
insufcientsuction.
1.9 Gas oven operating values (for gas versions only)
Model SBHG061 SBTG061 SEHG101 SETG101 SEHG102 SETG102 SEHG201 SETG201 SEHG202 SETG202
Voltage 1N 230V 1N 230V 1N 230V 1N 230V 1N 230V 1N 230V 1N 230V 1N 230V 1N 230V 1N 230V
Frequency (Hz) 50 50 50 50 50 50 50 50 50 50
Absorbed power
(kW)
1�4 0�4 1�7 0�7 3�3 0�8 3�3 0�8 4�1 1�6
Nom� heat input (kW)
12 12 19 19 27 27 36 36 54 54
Section power
cable (mm
2
)
3 x 1�5 3 x 1�5 3 x 1�5 3 x 1�5 3 x 1�5 3 x 1�5 3 x 1�5 3 x 1�5 3 x 1�5 3 x 1�5
Nominal heat input
Gas consumption
SExG061 SExG101 SExG102 SExG201 SExG202
G30 kg/h 0�94 1�49 2�13 2�84 4�26
G20 m
3
/h
1�26 2�01 2�86 3�81 5�71
G25 m
3
/h
1�47 2�33 3�32 4�43 6�65