55
Name Description Actions SOLUTION
E06 -
Chamber
safety
switch
Chamber thermal breaker Cooking cycle
block; automatic
reset�
If the problem persists, contact
the support centre�
E07 -
PWM
PWM board error
(communication timeout
or problems on fan speed)
Cooking cycle
block�
Contact the support centre�
E08 -
PWM 2
Second PWM board error
(communication timeout
or problems on fan speed)
Cooking cycle
block�
Contact the support centre�
E04 - Air
Flow
Airowratealarmongas
burner
Cooking cycle
block, manual
reset�
Check the obstructions of the
combustion fumes exhaust
chimney, otherwise contact the
assistance centre�
E18 - Air
Flow 2
Airowratealarmon
second gas burner
Cooking cycle
block, manual
reset�
Check obstructions to the
combustion fumes discharge
chimney, otherwise contact
after-sales assistance�
E14 - Hi
temp
Temperature inside the
technical compartment is
too high
Cooking cycle
block; automatic
reset�
Check the cleanliness of the
ventilationlter,theperimeter
ventilation of the oven (slots)
and the correct operation of the
components cooling fans�
E21 - No
water
There is no water to
generate steam
Cooking cycle
block; automatic
reset�
Check the connection to water
pipeline and make sure the
shut-off valve is open�
E24 - No
Water
litre-
meter
Litre-meter, washing
alarm
Washing block,
manual restore
Press the manual restore
(encoder button) If the problem
persists, contact the support
centre�
E09 -
Com PWM
PWM board
communication error
Cooking cycle
block�
Cut off the power and power
again� If the problem persists,
contact the support centre�
E10 -
Com
PWM2
PWM2 board
communication error
Cooking cycle
block�
Cut off the power and power
again� If the problem persists,
contact the support centre�
E16 -
Communi-
cation
Main board
communication failure
Cooking cycle
block�
Cut off the power and power
again� If the problem persists,
contact the support centre�
E23 - No
drain
The water in the boiler is
not drained correctly
Cooking cycle
block�
Cut off the power and power
again� If the problem persists,
contact the support centre�
E22 -
Power fail
Electric power supply is
interrupted
Cooking cycle
block�
Press M for 1 second�
E19 -
Probe 4
Moisture control probe 4
alarm
Cooking cycle
block�
Replace the moisture control
probe 4
E20 -
Probe 5
Moisture control probe 5
alarm
Cooking cycle
block�
Replace the moisture control
probe 5