139
value by utility grid or PV when the system is running
on-grid. So that the battery SOC is sufficient to
maintain normal working when the system is off-grid.
7
Immediate Charging
Enable to charge the battery by the grid immediately.
Take effect once. Enable or Disable based on actual
needs.
8
SOC For Stopping
Charging
Stop charging the battery once the battery SOC
reaches SOC For Stopping Charging.
9
Immediate Charging
Power
Indicates the percentage of the charging power to the
inverter rated power when enabling Immediate
Charging.
For example, setting the Immediate Charging Power of
a 10kW inverter to 60 means the charging power of
the inverter is 10kW*60%=6kW.
Method II: Setting via LCD
Setting SOC Protection, Depth of discharge (On-grid), Depth of discharge (Off-grid), Backup
SOC Holding
Step 1: Click on the screen or select the settings icon > Quick Setting > BAT
Setting>GOODWE/Default/Others through the button, select the model from the
optional list, and enter the settings page.
Step 2: Set parameters according to actual needs.