62
of conductor: 25mm²
LX U5.0-30, cross sectional area
of conductor: 25mm²
5
AC cable
AC input and output cables of
inverter (BACKUP/GRID):
Cross sectional area of
conductor: 16mm² or 4AWG
Outer diameter of multi-core
outdoor copper cable: 23.3mm-
24.8mm
Outer diameter of single-core
outdoor copper cable: 9.5mm-
9.9mm
Generator power cable (GEN):
Cross sectional area of
conductor: 10mm² or 6AWG
Multi-core outdoor copper
cable outer diameter: 20mm-
21mm
Outer diameter of single-core
outdoor copper cable: 8.3mm-
8.7mm
Prepared by
customers.
6
Smart meter power
cable
Outdoor copper cable
Conductor cross-sectional area:
1mm²
Prepared by
customers.
7
Battery
communication
cable
Communication between batteries and
inverters as well as between batteries
requires the use of CAT 5E or above
standard shielded network cables and
RJ45 shielded connector.
Prepared by
customers.
LX A5.0-30:
Supports purchase
from GoodWe
8
Smart meter RS485
Shielded twisted pair cable
Prepared by