P a g e | 51
DP752/DP730/DP722 Administration Guide
Version 1.0.11.4
SIP T2 Timeout
Identifies maximum retransmission interval for non-INVITE requests and INVITE
responses. Retransmitting and doubling of T1 continues until it reaches T2 value.
Default is 4 seconds.
SIP Timer D
Configures SIP timer D defined in RFC3261. Range of values 0-64. Default is 0.
Enable OPTIONS
Keep Alive
Enables OPTIONS Keep Alive, to check SIP server.
Default is No.
OPTIONS Keep
Alive Interval
Time interval for OPTIONS Keep Alive feature in seconds. Range of values is
1–64800. Default is 30.
OPTIONS Keep
Alive Max Lost
Maximum number of lost packets for OPTIONS Keep Alive feature before the phone
sends a re-registration. Range of values 3-10.
Default is 3.
Remove OBP from
Route
Removes outbound proxy information from “Route” header when sending SIP
packets. Default is No.
Support SIP
Instance ID
Adds “SIP Instance ID” attribute to Contact” header in REGISTER request as
defined in IETF SIP outbound draft. Default is Yes.
Hold Target Before
Refer
Sends re-INVITE to hold transfer target before sending REFER message to
transferee. Default is No.
Refer-To Use Target
Contact
Includes target’s “Contact” header information in “Refer-To” header when using
attended transfer. Default is No.
SUBSCRIBE for
MWI
Sends periodic “SUBSCRIBE” requests (depends on “Register Expiration”
parameter) for message waiting indication service. Default is No.
Enable 100rel
Appends “100rel” attribute to the “required” header of the initial signaling messages.
Default is No.
TEL URI
Indicates E.164 number in “From” header by adding “User=Phone” parameter or
using “Tel:” in SIP packets, if the base has an assigned PSTN Number.
Disabled: Will use “SIP User ID” information in the Request-Line and “From”
header.
User=Phone: “User=Phone” parameter will be attached to the Request-Line
and “From” header in the SIP request to indicate the E.164 number. If set to
"Enable".
Enabled: "Tel:" will be used instead of "sip:" in the SIP request.
Please consult your carrier before changing this parameter. Default is Disabled.

Table of Contents

Other manuals for Grandstream Networks DP730

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grandstream Networks DP730 and is the answer not in the manual?

Grandstream Networks DP730 Specifications

General IconGeneral
BrandGrandstream Networks
ModelDP730
CategoryCordless Telephone
LanguageEnglish

Related product manuals