6 – 5
Error messages in GP-GL command mode
Error message Cause Solution
GP-GL ERROR 1 An unrecognizable command was received.
Noise was received when the computer was turned
on.
Press the ENTER key to cancel the
error.
The software command settings for controlling the
cutting plotter have been changed.
Set the software command settings
for controlling the cutting plotter.
The data-transmission settings have been changed in
the interface settings.
Set the correct data-transmission
conditions.
GP-GL ERROR 2 The command terminator is incorrect.
The software settings for the output device have been
changed.
Set the software command settings
for controlling the cutting plotter.
The data-transmission settings have been changed in
the interface settings.
Set the correct data-transmission
conditions.
GP-GL ERROR 3 The command delimiter is incorrect.
The software settings for the output device have been
changed.
Set the software command settings
for controlling the cutting plotter.
The data-transmission settings have been changed in
the interface settings.
Set the correct data-transmission
conditions.
GP-GL ERROR 4 The command parameter exceeds the permissible
range.
The software settings for the output device have been
changed.
Set the software command settings
for controlling the cutting plotter.
The data-transmission settings have been changed in
the interface settings.
Set the correct data-transmission
conditions.
GP-GL ERROR 5 An error occurred in the reception of data within the
interface.
The software command settings for controlling the
cutting plotter have been changed.
Set the software command settings
for controlling the cutting plotter.
The data-transmission settings have been changed in
the interface settings.
Set the correct data-transmission
conditions.