FC9000-UM-251-9370 12-8
12 Target electrical component for WEEE instruction
• Removing (C) Y Relay Board
(1) Remove the four M4L6 binding head screws from the right side cover.
(2) Detach the right side cover.
M4L6 binding head screw
Right side cover
(3) Disconnect the control panel exible cable from the main board.
(4) Remove the four M3L6 binding head screws holding the control panel assembly, and then detach it.
M3L6 binding head screw
Control panel assembly