EasyManua.ls Logo

Grundfos TPE2 - Page 23

Grundfos TPE2
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Terminal Type Function
NC
Normally closed
contact
Signal relay 1
LIVE or PELV
C1 Common
NO
Normally open
contact
NC
Normally closed
contact
Signal relay 2
PELV only
C2 Common
NO
Normally open
contact
18 GND Earth
11 DI4/OC2
Digital input and
output, configurable.
Open collector: Max.
24 V resistive or
inductive.
19
Pt100/1000 input
2
Pt100/1000 sensor
input
17
Pt100/1000 input
1
Pt100/1000 sensor
input
12 AO
Analog output:
0-20 mA / 4-20 mA
0-10 V
9 GND Earth
14 AI3
Analog input:
0-20 mA / 4-20 mA
0-10 V
1 DI2
Digital input,
configurable
21
LiqTec sensor
input 1
LiqTec sensor input
white conductor
20 GND
Earth
brown and black
conductors
22
LiqTec sensor
input 2
LiqTec sensor input
blue conductor
10 DI3/OC1
Digital input or output,
configurable.
Open collector:
maximum 24 V
resistive or inductive.
Terminal Type Function
4 AI1
Analog input:
0-20 mA / 4-20 mA
0.5 - 3.5 V / 0-5 V /
0-10 V
2 DI1
Digital input,
configurable
5 +5 V
Supply to
potentiometer and
sensor
6 GND Earth
A GENIbus, A GENIbus, A (+)
Y GENIbus, Y GENIbus, GND
B GENIbus, B GENIbus, B (-)
3 GND Earth
15 +24 V Supply
8 +24 V Supply
26 +5 V
Supply to
potentiometer and
sensor
23 GND Earth
25 GDS TX
Grundfos Digital
Sensor output
24 GDS RX
Grundfos Digital
Sensor input
7 AI2
Analog input:
0-20 mA / 4-20 mA
0.5 - 3.5 V / 0-5 V /
0-10 V
23
English (GB)

Table of Contents

Related product manuals