21. Grundfos Eye
The operating condition of the pump is indicated by
Grundfos Eye on the control panel. See figure
Grundfos Eye, A.
TM055993
Grundfos Eye
Grundfos Eye Indication Description
No lights are on.
The power is off.
The pump is not running.
The two opposite green indicator lights
are rotating in the direction of rotation of
the pump when seen from the non-drive
end.
The power is on.
The pump is running.
The two opposite green indicator lights
are permanently on.
The power is on.
The pump is not running.
One yellow indicator light is rotating in
the direction of rotation of the pump when
seen from the non-drive end.
Warning.
The pump is running.
One yellow indicator light is permanently
on.
Warning.
The pump has stopped.
The two opposite red indicator lights are
flashing simultaneously.
Alarm.
The pump has stopped.
84
English (GB)