Enclosure class
Standard: IP55 (IEC 34-5).
Optional: IP66 (IEC 34-5).
Insulation class
F (IEC 85).
Standby power consumption
5-10 W.
Cable entries
Motor size
[kW]
Number and size of cable entries
0.25 - 2.2 4 x M20
34.1 Torques
Terminal Thread size
Maximum
torque
[Nm]
L1, L2, L3, L, N M4 2.35
NC, C1, C2, NO M2.5 0.5
1 to 26 and A, Y, B M2 0.5
Related information
34.2 Sound pressure level
34.2 Sound pressure level
Pump type
Sound pressure level
ISO 3743
[dB(A)]
TPE2/TPE3 32-80 55
TPE2/TPE3 32-120 60
TPE2/TPE3 32-150 65
TPE2/TPE3 32-180 66
TPE2/TPE3 32-200 66
TPE2/TPE3 40-80 52
TPE2/TPE3 40-120 59
TPE2/TPE3 40-150 60
TPE2/TPE3 40-180 63
TPE2/TPE3 40-200 65
TPE2/TPE3 40-240 66
TPE2/TPE3 50-60 48
TPE2/TPE3 50-80 56
TPE2/TPE3 50-120 60
TPE2/TPE3 50-150 60
TPE2/TPE3 50-180 63
TPE2/TPE3 50-200 64
TPE2/TPE3 50-240 66
TPE2/TPE3 65-60 44
TPE2/TPE3 65-80 51
TPE2/TPE3 65-120 59
TPE2/TPE3 65-150 60
TPE2/TPE3 65-180 62
TPE2/TPE3 65-200 62
TPE2/TPE3 80-40 43
TPE2/TPE3 80-120 53
TPE2/TPE3 80-150 62
TPE2/TPE3 80-180 64
TPE2/TPE3 100-40 43
TPE2/TPE3 100-120 53
TPE2/TPE3 100-150 62
TPE2/TPE3 100-180 64
99