26. Changing the position of the
control panel
DANGER
Electric shock
Death or serious personal injury
‐ Switch off the power supply to the
motor and to the signal relays. Wait at
least 5 minutes before starting any
work on the motor. Make sure that the
power supply cannot be accidentally
switched on.
You can turn the control panel 180 °. Follow the
instructions below.
1. Loosen the four screws, TX25, of the terminal box
cover.
TM055351
Loosening the screws
2. Remove the terminal box cover.
TM055352
Removing the terminal box cover
3. Press and hold in the two locking tabs, A, while
gently lifting the plastic cover, B.
TM055353
Lifting the plastic cover
4. Turn the plastic cover 180 °.
Do not twist the cable more than 90 °.
TM055354
Turning the plastic cover
5. Position the plastic cover correctly on the four
rubber pins, C. Make sure that the locking tabs, A,
are placed correctly.
TM055355
Positioning the plastic cover
6. Fit the terminal box cover, and make sure that it is
also turned 180 ° so that the buttons on the
control panel are aligned with the buttons on the
plastic cover.
7. Tighten the four screws, TX25, with 5 Nm.
TM055356
Fitting the terminal box cover
91