EasyManua.ls Logo

Grundfos TPE2 - 29 Fault Finding; The Motor Does Not Run When Started; Motor Alarm When the Power Supply Is Switched on; Occasional Motor Alarm

Grundfos TPE2
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29. Fault finding
DANGER
Electric shock
Death or serious personal injury
Switch off the power supply to the
motor and to the signal relays. Wait at
least 5 minutes before starting any
work on the motor. Make sure that the
power supply cannot be accidentally
switched on.
DANGER
Magnetic field
Death or serious personal injury
Do not handle the motor or rotor if you
have a pacemaker.
WARNING
Hazardous liquids
Death or serious personal injury
If the pump is used for a liquid which is
injurious to health, it will be classified
as contaminated. In such cases, take
proper precautions to avoid injury to
health when operating or working on
the pump.
Wear personal protection equipment.
CAUTION
Hot or cold liquids
Minor or moderate personal injury
Wear personal protection equipment.
29.1 The motor does not run when started
Cause Remedy
Supply failure. Check the electrical connection.
Remedy, if necessary.
The fuses are blown. Replace the fuse.
The motor is defective. Replace the motor.
29.2 Motor alarm when the power supply is switched on
Cause Remedy
Supply failure. Check the electrical connection.
Remedy, if necessary.
The cable connection is loose or faulty. Repair cable connection.
The motor winding is defective. Repair the motor.
The pump is mechanically blocked. Clean the pump.
29.3 Occasional motor alarm
Cause Remedy
The supply voltage is periodically too low or too high. Make sure the input supply voltage stable.
29.4 No motor alarm, but the pump does not run
Cause Remedy
Check the power supply. Make sure the power supply connected.
Check the fuses. Replace the fuse, if defective.
29.5 The pump performance is not constant
Cause Remedy
The pump inlet pressure is too low. Increase the inlet pressure.
The inlet pipe or pump is partly is blocked by
impurities.
Clean the inlet pipe or pump.
94