3. Remove the securing screw (A).
TM064082
Removing the securing screw
4. Fit the CIM module by aligning it with the three
plastic holders (A) and the connecting plug (B).
Press home the module using your fingers.
TM064083
Fitting the CIM module
5. Fit and tighten the securing screw (A) to 1.3 Nm.
6. Make the electrical connections to the CIM
module as described in the instructions delivered
with the module.
7. Connect the cable screens of the bus cables to
earth via one of the earth clamps (A).
TM064195
Connecting the cable screens to earth
8. Route the wires for the CIM module. See the
example below.
TM064085
Example of wire routing
9. Fit the CIM cover.
88
English (GB)