8.3 Malfunctions / Troubleshooting
Malfunction Cause Measure
Lubrication system
does not lubricate
(Pump function has
been stopped.)
Overpressure • Check lubrication lines
• Rectify causes (defective
lubrication line, hardened
lubricant, etc.)
• Reset the error
ÜChapter5.5.2.3,251
Lubrication system
does not lubricate
(Pump function has
been stopped.)
Undervoltage or
overvoltage
• Switch off lubrication sys-
tem
• Check supply voltage and
compare with specified
parameters
• Replace defective elec-
tronic components
• Switch on lubrication sys-
tem
• Reset the error
ÜChapter5.5.2.3,251
Lubrication system
does not lubricate
(Pump function has
been stopped.)
Internal error Disassemble entire lubrica-
tion system with screwed
on lubricant cartridge and
send back to Güdel along
with a comprehensive fault
description.
Lubrication system
does not lubricate
(Pump function has
been stopped.)
• Lubricant car-
tridge missing
• Lubricant car-
tridge empty
• Air in the lubrica-
tion system
• Insert new lubricant car-
tridge
• Vent the lubrication sys-
tem
The lubrication system con-
tinues running without
change
Tab.8-1 Malfunctions / Troubleshooting
Repairs OPERATING MANUAL Lubrication system FlexxPump4D
9007202674126091_v2.0_EN-US
106