Malfunction Cause Measure
Lubrication system does not lubricate
(Pump function has been stopped.)
Overpressure Check lubrication lines
Rectify causes (defective lubrication line, hardened lubricant, etc.)
Reset the error ÜChapter5.5.2.3,251
Lubrication system does not lubricate
(Pump function has been stopped.)
Undervoltage or overvoltage Switch off lubrication system
Check supply voltage and compare with specified parameters
Replace defective electronic components
Switch on lubrication system
Reset the error ÜChapter5.5.2.3,251
Lubrication system does not lubricate
(Pump function has been stopped.)
Internal error Disassemble entire lubrication system with screwed on lubricant cartridge
and send back to Güdel along with a comprehensive fault description.
Tab.5-5 Malfunctions / Troubleshooting
Commissioning OPERATING MANUAL Lubrication system FlexxPump4D
9007202674126091_v2.0_EN-US
60