9.4.1.1 Cleaning the rails and racks
DANGER
Moving the axis
The work requires moving the axis. This can lead to severe or fatal injuries!
Ensure that no persons are in the danger area while the axis is moving
CAUTION
Risk of injury
There is a risk of cuts and crushing in the area of the gearbox, pinion, and
racks.
Wear appropriate protective clothing
Fig.9-1 Cleaning rails and racks
Cleaning agents
mild universal cleaner free from aromatic compounds (e.g. Motorex OPAL
5000)
Tab.9-1 Cleaning agents: Rails and racks
Clean the rails and racks as follows:
1 Switch off the system and secure it with a padlock against being switched
on again
2 Clean the rails and racks thoroughly
The rails and racks have been cleaned.