5.5.4 Lubrication recommendation
5.5.4.1 General information
NOTE
Lubricating film missing
A missing lubricating film on rails and racks leads to damage to the product.
This results in operational failure.
Ensure that there is always a lubricating film on rails and racks during oper-
ation
Perform the described tasks at the specified times
Perform lubrication work at the latest when the first signs of tribocorro-
sion (reddish discoloration of the track) are visible
Adjust lubrication interval if necessary
The running surfaces of rails, racks as well as the drive pinions need to be lu-
bricated. A precise recommendation on the lubrication quantity needed can-
not be made, because that depends on various factors. The calculations listed
here are based on empirical values and lead to reference values. The lubrica-
tion quantity needs to be checked regularly and needs to be adapted if neces-
sary.
The following non-conclusive factors determine the lubrication quantity:
Kilometers traveled by the axle
Degree of contamination of the axle
Power-on time of the entire plant
Ambient temperature
Number of lubrication points
Elements used in the lubrication system
Güdel recommends to program the HMI user interface so that the operator
of the entire system can adjust the lubrication quantity to the operating con-
ditions. The operator is always responsible for adequate and properly func-
tioning lubrication.
These recommendations are valid exclusively for systems that are connected
according to the Güdel standard. Ü239
Commissioning
OPERATING MANUAL Lubrication system
FlexxPump4D
9007202674126091_v2.0_EN-US
61