7.3.2 Maintenance tasks after 2,200 hours
7.3.2.1 Replacing lubricant cartridge
Replace the lubricant cartridge if the malfunction message E1 (Empty) appears.
DANGER
Residual amounts in empty lubricant cartridges
Empty lubricant cartridges contain lubricant residues. Oils and greases are
harmful to the environment!
• Dispose of the lubricant cartridge in an environmentally friendly manner
Replace the component every 2,000 operating hours or after 1 year at the
latest.
Use only original Güdel lubricant cartridges Never refill the lubricant car-
tridges!
Maintenance
OPERATING MANUAL Lubrication system
FlexxPump4D
9007202674126091_v2.0_EN-US