7.3.4 Maintenance tasks after 20,000 hours
7.3.4.1 Replacing the lubricant pump
Removing the lubricant pump
Remove the lubricant pump as follows:
1 Switch off the system and secure it with a padlock against being switched
on again
2 Remove connecting cable
3 Disconnect the lubrication lines from the hydraulic outputs
4 Loosen the screws
5 Remove the lubricant pump
The lubricant pump has been removed.
Replacing the lubricant pump
Replace the lubricant pump as follows:
1 Replace the lubricant pump
2 Replace the connection cable
3 Replace the lubrication line
The lubricant pump has been replaced.