EasyManua.ls Logo

HEIDENHAIN ITNC 530 - CYCLE PROGRAMMING - Page 379

HEIDENHAIN ITNC 530 - CYCLE PROGRAMMING
513 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HEIDENHAIN iTNC 530 379
15.10 DATUM CIRCLE CENTER (Cycle 416, DIN/ISO: G416)
U Datum number in table Q305: Enter the number in the
datum or preset table in which the TNC is to save the
coordinates of the bolt-hole circle center. If you enter
Q305=0, the TNC automatically sets the display so
that the new datum is on the bolt hole center. Input
range 0 to 2999
U New datum for reference axis Q331 (absolute):
Coordinate in the reference axis at which the TNC
should set the bolt-hole center. Default setting = 0.
Input range: –99999.9999 to 99999.9999
U New datum for minor axis Q332 (absolute):
Coordinate in the minor axis at which the TNC should
set the bolt-hole center. Default setting = 0. Input
range: –99999.9999 to 99999.9999
U Measured-value transfer (0, 1) Q303: Specify
whether the determined datum is to be saved in the
datum table or in the preset table:
-1: Do not use. Is entered by the TNC when old
programs are read in (see “Saving the calculated
datum” on page 344).
0: Write determined datum in the active datum table.
The reference system is the active workpiece
coordinate system.
1: Write determined datum in the preset table. The
reference system is the machine coordinate system
(REF system).

Table of Contents