EasyManua.ls Logo

Heinzmann CargoPower - Page 63

Default Icon
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 System settings and service software
CargoPower installation and operation, revision - 01 57
Torque- / rotation sensor
The "gradient of rise" determines the time in which the torque input by the sensor
reaches the maximum value.
The gradient should not be higher than 1000 Nm/s!
The "return gradient" determines the time in which the torque input by the sensor
reaches zero after the pedaling has stopped. This value can be used to regulate the
so-called "push-back".
The return gradient must be at least 500 Nm/s and should not be selected higher
than 2000 Nm/s!
Safety relevant setting
This value is safety-relevant according to DIN EN 15194.
This value must not be changed arbitrarily!
Starting/push aid
Starting aid:
The starting aid is switched on with the selection field "Starting aid activated".
In addition, a value must be entered under "Speed limit Starting aid". From
this value onwards, the support by the motor is interrupted when starting up.
The gradient of rise must not be selected higher than max. 1000 Nm/s!
The return gradient must be at least 500 Nm/s and must not be selected higher than
2000 Nm/s!
Safety relevant setting
This value is safety-relevant according to DIN EN 15194.
This value must not be changed arbitrarily!
Pushing aid:
If this function is activated, the assistance from the throttle grip only starts after
the system registers a forward movement of the motor.

Table of Contents