6 System settings and service software
CargoPower installation and operation, revision - 01 58
Reversing
With the selection field "Reversing allowed", the function for reversing can be
activated. The prerequisite is that a button for reversing is installed on the vehicle.
When this button and the throttle handle/thumb are pressed simultaneously, the vehicle
drives backwards.
The gradient of rise must not be chosen higher than 1000 Nm/s!
The return gradient must be at least 500 Nm/s and must not be selected higher than
2000 Nm/s!
Safety relevant setting
This value is safety-relevant according to DIN EN 15194.
This value must not be changed arbitrarily!
Motor
Limitation of continuous power:
This field displays the maximum continuous rated power of the motor.
Safety relevant setting
This value is safety-relevant according to DIN EN 15194.
The total system must not exceed a rated continuous power of 250W.
This means that in a primary/secondary system, the power limit of the
primary and secondary motor is set to 125W each!
Direction of rotation
Sets the direction of rotation of the motor.
6.1.6.6 "Maintenance" tab
(see dashboard 1.12 and following)
Under the "Maintenance" tab, you can view the operating hours and the odometer of
the controller as well as the odometer of the vehicle.
In addition, the vehicle's odometer can be set to a new value. This function is used
when replacing a controller on a vehicle already in operation.