EN – Translation of the original user manual - 2.0 | 2019
Parameter set Version of the installed parameter table
Bootloader motor Version of the bootloader program of the motor
controller
Bootloader peri. Version of the bootloader program of the
periphery controller
2. Service access
Password input Access (password) for the service engineer and
activation of additional performance features
National language Selection of a different display language in the LC
display
Motor dir. of rotation Change of the motor direction of rotation left/right
Time pre-limit switch Setting of the time for the braking curve before
the limit positions are reached
3. Diagnosis
Gate status Status of control system /gate, inputs and outputs
and of maintenance information
Sensor status Setting and status of connectable sensors
System log book Table of the most recent events and faults
including their time stamp (operating time)
Temperature Display of the temperatures of the power
electronics
Motor current Display of the maximum motor currents that have
occurred
4. Settings
Set timer Menu for setting various different timers (closing
movement times etc.)
Input: In3/4 Selection of functions at the two inputs In3 and
In4
Safety Selection of the installed safety sensors on the
gate
Special parameters Settings for maintenance requirements
Operating mode Selection of hold-to-run operation or automatic
mode
Parameter backup Menu for parameter backup settings
Status notification Settings for gate status notifications as relay
output
5. Radio remote control
Active transmitters Display of the number of registered radio
transmitters
Register transmitter Register new handheld transmitters with the
functions predefined in the program
Register trans. OPEN Register new handheld transmitter (key) for the
OPEN function
Register trans.CLOSE Register new handheld transmitter (key) for the
CLOSE function