EN – Translation of the original user manual - 2.0 | 2019
The special emergency operating mode has been
activated
Software restart triggered by the program
EMERGENCY STOP 9
The HMD24 does not have an emergency stop system. According to the Machine
Directive 2006/42/EC, annex 1, article 1.2.4.3., this is not necessary if the
emergency stop system would not lower the risk. However, an emergency stop
system can be connected to the HMD24. Please refer to the instruction in the
installation manual.
MAINTENANCE INSTRUCTIONS 10
When working on the gate or cleaning it, the power supply to the system
must be switched off and protected from unauthorized switching on.
If the gate must be moved manually, first turn the system circuit breaker in
themotor cabinet to the "off" position and protect it from being switched on
(e.g. by locking the cabinet).
10.1 GATE MAINTENANCE
Under normal conditions and with regular maintenance, sliding gates have a life of
at least 200,000 cycles. To ensure that your gate operates safely, reliably and in
compliance with all relevant legislation and laws, we recommend a MINIMUM of
one maintenance check every 12 months or after 10,000 operating cycles,
whichever is the sooner. However, to ensure safety and proper operation of the
gate, more frequent maintenance checks are recommended during the lifetime of
the gate.
Any maintenance work, including repair, replacement, modification and upgrade
MUST be conducted by a Heras trained, qualified, competent and certified