EN – Translation of the original user manual - 2.0 | 2019
Reference/
Error no.
Text
Meaning
230
REL+err.Idl
The voltage monitoring system for the release
signal has measured an excessively high value
for the idle voltage
231
DCtstCuHigh
The test current at the DC power module is too
high
232
DCtstCuLow
The test current at the DC power module is too
low
233
DcCuHigh
The DC power module has detected an
excessively high motor current
234
INC-Sensor OP
Incremental sensor value in OPEN direction too
low
235
INC-Sensor CL
Incremental sensor values in CLOSE direction too
low
236
Reference active
A reference movement of the gate was activated
238
OPEN/CLOSE-
StartActive
The program start of the motor controller was
interrupted due to an active movement command
(Check inputs)
239
LightbarrierTst.err
The light barrier test has shown up an error
240
EMERGENCYtst.err
The self-test failed at the emergency input
241
SPI BCC err
A checksum error occurred during
communication between the controllers
242
SPI ID Val
A data error was detected during communication
between the controllers
243
Parameter.err
An error occurred when writing data into the
memory
244
EMERGENCYSTOPtst.e
rr
The self-test on the EMERGENCY STOP input
failed
247
Variants.err
The loaded parameter set and the program
variant of the controller do not match
248
Param.Load.err.
An error was detected when transferring the
parameter set from the periphery controller to
the motor controller (CRC16 checksum)
249
Menu pointer err
Menu program pointer error
(Error in menu structure branching)
250
ProgramInit.
In system log: The program was initialised
(deletion and initialisation of the parameter
memory)