power failure. The entered time relates to the number of hours that have passed
since the control system was put into operation for the first time. This log shows
the last actions of the gate and any errors that have occurred.
The first line of the display shows the time of the entry. The second line starts
with a number with up to three digits that corresponds to a reference number
from the parameter table. This is followed by a corresponding text that is also
stored in the parameter table. By turning the selection switch it is possible to
scroll through the entries in this log memory in chronological order. The very first
entry in this log always contains information about the program initialisation
([250] ProgramInit.). The specific deletion of this data is not possible. Only the
initialisation of the entire parameter memory will reset this system log book.
The system log book is displayed as follows:
Menu: “Service Access”, “Password Input”: Enter password
Menu: “Diagnosis”, activate “System log book”
Display
Meaning
Log system
Start
Rotating the selection switch to the left takes you to the
start of the sensor table
0 =>
250
ProgramInit
Program initialisation (first entry in the memory)
. . .
HHH =>
253 RESET
Log entry due to a reset of control system
(e.g. after exiting the menu)
. . .
Log system
End
End of the log system memory reached