101
Pn No.
Size
Name
Setting range
Setting Unit
Factory
setting
Available
time
Categor
y
Model
Pn518
2
Input signal inversion
setting 2
0000~1111
-
0000
Power
restart
Setup
-
n.

X
CN1-IN4 terminal input signal inversion
0
Not reverse signal.
1
Reverses the signal.
n.X
CN1-IN5 terminal input signal inversion
0
Not reverse signal.
1
Reverses the signal.
n.X
CN1-IN6 terminal input signal inversion
0
Not reverse signal.
1
Reverses the signal.
n.X

CN1-IN7 terminal input signal inversion
0
Not reverse signal.
1
Reverses the signal.
Pn51B
4
Between motor-load
position
Excessive deviation
detected value
0~1073741824
1
Command
unit
1000
Effective
immediately
Setup
Pn51E
2
Warning value for
excessive position
deviation
10~100
1%
100
Effective
immediately
Setup
Pn520
4
Position deviation is too
large warning value
1~1073741823
1
Command
unit
5242880
Effective
immediately
Setup
Pn522
4
Positioning completion
amplitude
0~1073741824
1
Command
unit
7
Effective
immediately
Setup
Pn524
4
NEAR signal range
1~1073741824
1
Command
unit
107374182
4
Effective
immediately
Setup
Pn526
4
Warning value for
excessive position
deviation when servo ON
1~1073741823
1
Command
unit
5242880
Effective
immediately
Setup
Pn528
2
Warning value for
excessive position
deviation when servo ON
10~100
1%
100
Effective
immediately
Setup
Pn529
2
The speed limit value when
the servo ON
0~10000
1 min
-1
10000
Effective
immediately
Setup
Pn52A
2
The product value of 1
circle of full closed loop
rotation
0~100
1%
20
Effective
immediately
Adjust
ment
Pn52B
2
Overload warning value
1~100
1%
20
Effective
immediately
Setup
Pn52C
2
Motor overload detection
base current decreases
ratings
10~100
1%
100
Power
restart
Setup
Pn52F
2
Monitoring display when
power is turned on
0000~0FFF
-
0FFF
Effective
immediately
Setup
Pn530
2
Program JOG run class
switch
0000~0005
-
0000
Effective
immediately
Setup
n.

X
Program JOG run parameter
0
(waiting time Pn535→ forward movement Pn531) * number of movements Pn536
1
(waiting time Pn535→ reverse movement Pn531) * number of movements Pn536
2
(waiting time Pn535→ forward movement Pn531) * number of movements Pn536
(waiting time Pn535→ reverse movement Pn531) * number of movements Pn536
3
(waiting time Pn535→ reverse movement Pn531) * number of movements Pn536
(waiting time Pn535→ forward movement Pn531) * number of movements Pn536
4
(waiting time Pn535→ forward movement Pn531→ waiting time Pn535→ reverse
movement Pn531)× number of movements Pn536
5
(wait time Pn535→ reverse movement Pn531→ wait time Pn535→ forward
movement Pn531)× movement times Pn536
n.X
Appointment parameters (do not change it)
n.X
Appointment parameters (do not change it)
n.X
Appointment parameters (do not change it)
Pn531
4
Program JOG move
distance
0~1073741824
1
Command
unit
32768
Effective
immediately
Setup
Pn533
2
Program JOG movement
speed
1~10000
1 min
-1
500
Effective
immediately
Setup
Pn534
2
Program JOG acceleration
and deceleration time
2~10000
1 ms
100
Effective
immediately
Setup
Pn535
2
Program JOG wait time
0~10000
1 ms
100
Effective
immediately
Setup
Pn536
2
Number of program JOG
moves
0~1000
Times
1
Effective
immediately
Setup

Table of Contents