OM-285922 Page 34
6-6. Controls, TIG Mode (Menu 3 Of 5)
1 Process Select Button
In the TIG process when the option-
al foot control is not being used, the
output is on when the TIG process
is selected.
Push button to enter TIG process.
Check weld parameter chart for
correct polarity at positive (+) and
negative () receptacles.
See section 5-9 for proper cable
placement.
2 Amperage Knob
Adjust amperage knob per weld pa-
rameter chart for initial setting.
3 Display
4 Live Output signal
. When the symbol is activated
on the display the output is on.
5 Voltage Displayed
The voltage is displayed only during
welding.