EasyManua.ls Logo

Hobart Multi-Handler 200 - Electrode and Amperage Selection Chart

Hobart Multi-Handler 200
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OM-285922 Page 61
12-16.Common GMAW (MIG) Shielding Gases
This is a general chart for common gases and where they are used. Many different combinations (mixtures) of shielding gases have been developed
over the years. The most commonly used shielding gases are listed in the following table.
Application
Gas
Spray Arc
Steel
Short
Circuiting
Steel
GMAW-P
Steel
Spray Arc
Stainless
Steel
Short
Circuiting
Stainless
Steel
GMAW-P
Stainless
Steel
Spray Arc
Aluminum
Short
Circuiting
Aluminum
GMAW-P
Aluminum
Argon
All
Positions
All
Positions
All
Positions
All
Positions
Argon + 1% O
2
Flat &
Horizontal
Fillet
All
Positions
Flat &
Horizontal
Fillet
Argon + 2% O
2
Flat &
Horizontal
Fillet
All
Positions
Flat &
Horizontal
Fillet
Argon + 5%
CO
2
Flat &
Horizontal
Fillet
All
Positions
Argon + 10%
CO
2
Flat &
Horizontal
Fillet
All
Positions
All
Positions
Argon + 25%
CO
2
All
Positions
Argon + 50%
CO
2
All
Positions
CO
2
All
Positions
Helium
All
Positions
1
Argon +
Helium
All
Positions
1
90% HE +
7-1/2% AR +
2-1/2% CO
2
All
Positions
65% AR + 33%
HE + 2% CO
2
All
Positions
1 Heavy Thicknesses

Table of Contents

Related product manuals