6808 Manual — P/N LS10146-001SK-E:C 09/28/2017 11
Introduction
1.3 Compatible Products
The table below lists the products available from Honeywell Silent Knight for use with the 6808.
Input Point An addressable sensing device, such as a smoke or heat detector or a contact
monitor device.
Input Zone A protected area made up of input points.
Output Point (or Output Circuit) A notification point or circuit for notification appliances. Relay circuits and
auxiliary power circuits are also considered output points.
Group (or “Output Group”) A group of output points. Operating characteristics are common to all output
points in the group.
Output (or “Cadence”) Pattern The pattern that the output will use, for example, Constant, March Code, ANSI
3.41. Applies to zones and special system events. See Appendix D for additional
information.
Mapping Mapping is the process of specifying which outputs are activated when certain
events occur in the system. Section 8.2 explains mapping in detail.
Common Communication Link Up to 17 panels can be linked. Consist of any combination of 17 panels of these
model numbers:6700, 6808, 6820 / 6820EVS. For reporting purposes only. Not a
peer-to-peer networked system.
SWIFT Smart Wireless Integrated Fire Technology
Term Description
Table 1.1 Manual Terminology
Type of Device Model Description
SK
Addressable
SLC Devices
See Section Section 7.1 for a list of compatible devices.
SD
Addressable
SLC Devices
See Section Section 7.2 for a list of compatible devices.
SWIFT
Wireless SLC
Devices
See Section Section 7.3 for a list of compatible devices
Other Modules
5824 Serial/Parallel Printer
Interface Module
Allows a printer to be attached for the on-site event logging. Maximum of four
5824s per control panel.
5496 (Rev F or higher) NAC
Expander
Add 4 Notification/Auxiliary power circuits with
each 5496 NAC Expander.
5496 & 5895XLs can be
used in any combination,
up to a total of 8 devices on
one panel.
5895XL (Rev F or higher)
power supply
Provides additional power, six Flexput
®
circuits,
and two Form C relays. See Model 5895XL
Installation Instructions P/N 151142.
5860 and 5860R LCD
Annunciator
4x20 LCD fire annunciator. 5860 is gray; 5860R
is red.
Up to 12 5860, 6860 or
6855s per system.6860 LCD Annunciator 4x40 LCD remote fire annunciator
6855 LCD Annunciator 4x20 LCD remote fire annunciator
5860TG and 5860TR Trim Ring Trim ring kits for surface mounting the 5860 annunciator. 5860TG is gray;
5860TR is red.
5865-3 and 5865-4 LED
Annunciator
LED annunciator can display up to 30 LEDs (15
red and 15 yellow). 5865-4 has key switches for
silence and reset, and a system trouble LED.
5865-3, 5865-4, and 5880
can be used in any
combination, up to a total of
eight devices on one panel.
5880 LED I/O Module Driver for up to 40 LEDs. Interfaces with
customized annunciator boards. In addition the
5880 has eight generic switch input points.
5883 General Purpose Relay
Module
Provides 10 Form C relays. Designed to be driven by the 5880. Up to four,
5883s can be used with each 5880 module.
SK-NIC Network Interface Card Refer to LS10172-001SK-E
SK-FML Fiber-Optic Multi Mode, Receiver Refer to LS10178-001SK-E
SK-FSL Fiber-Optic Single Mode, Transmitter