6808 Manual  — P/N LS10146-001SK-E:C  09/28/2017 11
Introduction
1.3  Compatible Products
The table below lists the products available from Honeywell Silent Knight for use with the 6808.
Input Point An addressable sensing device, such as a smoke or heat detector or a contact 
monitor device. 
Input Zone A protected area made up of input points.
Output Point (or Output Circuit) A notification point or circuit for notification appliances. Relay circuits and 
auxiliary power circuits are also considered output points.
Group (or “Output Group”) A group of output points. Operating characteristics are common to all output 
points in the group.
Output (or “Cadence”) Pattern The pattern that the output will use, for example, Constant, March Code, ANSI 
3.41. Applies to zones and special system events. See Appendix D for additional 
information.
Mapping Mapping is the process of specifying which outputs are activated when certain 
events occur in the system. Section 8.2 explains mapping in detail.
Common Communication Link Up to 17 panels can be linked. Consist of any combination of 17 panels of these 
model numbers:6700, 6808, 6820 / 6820EVS. For reporting purposes only. Not a 
peer-to-peer networked system.
SWIFT Smart Wireless Integrated Fire Technology
Term Description
Table 1.1   Manual Terminology
Type of Device Model Description
SK 
Addressable 
SLC Devices
See Section Section 7.1 for a list of compatible devices.
 SD 
Addressable 
SLC Devices
See Section Section 7.2 for a list of compatible devices.
SWIFT 
Wireless SLC 
Devices
See Section Section 7.3 for a list of compatible devices
Other Modules
5824 Serial/Parallel Printer 
Interface Module
Allows a printer to be attached for the on-site event logging. Maximum of four 
5824s per control panel.
5496 (Rev F or higher) NAC 
Expander
Add 4 Notification/Auxiliary power circuits with 
each 5496 NAC Expander.
5496 & 5895XLs can be 
used in any combination, 
up to a total of 8 devices on 
one panel.
5895XL (Rev F or higher) 
power supply
Provides additional power, six Flexput
®
 circuits, 
and two Form C relays. See Model 5895XL 
Installation Instructions P/N 151142.
5860 and 5860R LCD 
Annunciator
4x20 LCD fire annunciator. 5860 is gray; 5860R 
is red.
Up to 12 5860, 6860 or 
6855s per system.6860 LCD Annunciator 4x40 LCD remote fire annunciator 
6855 LCD Annunciator 4x20 LCD remote fire annunciator
5860TG and 5860TR Trim Ring Trim ring kits for surface mounting the 5860 annunciator. 5860TG is gray; 
5860TR is red.
5865-3 and 5865-4 LED 
Annunciator
LED annunciator can display up to 30 LEDs (15 
red and 15 yellow). 5865-4 has key switches for 
silence and reset, and a system trouble LED.
5865-3, 5865-4, and 5880 
can be used in any 
combination, up to a total of 
eight devices on one panel.
5880 LED I/O Module Driver for up to 40 LEDs. Interfaces with 
customized annunciator boards. In addition the 
5880 has eight generic switch input points.
5883 General Purpose Relay 
Module
Provides 10 Form C relays. Designed to be driven by the 5880. Up to four, 
5883s can be used with each 5880 module.
SK-NIC Network Interface Card Refer to LS10172-001SK-E
SK-FML Fiber-Optic Multi Mode, Receiver Refer to LS10178-001SK-E
SK-FSL Fiber-Optic Single Mode, Transmitter