LS10143-001SK-E Reporting
12-2
Automatic test off normal RY 0 RYNN000000 1 608 00 000
Battery voltage trouble YT Exp. ID YTNNXX0000 1 302 Exp. ID 000
Battery voltage trouble restore YR Exp. ID YRNNXX0000 3 302 Exp. ID 000
Date changed event JD 0 JDNN000000 1 625 00 000
ECS Reset OR 1 ORNN000001 1 401 00 001
Emergency System Overridden QS 0 QSNN000000 1 244 00 000
Emergency System Overridden
Restore
QR 0 QRNN000000 3 244 00 000
Fire drill has begun FI 0 FINN000000 1 604 00 000
Fire drill has ended FK 0 FKNN000000 3 604 00 000
F1 Mapping Inhibited FT 2001 FTNN002001 1 570 00 001
F1 Mapping Inhibited Restoral FJ 2001 FJNN002001 3 570 00 001
F2 Mapping Inhibited FT 2002 FTNN002002 1 570 00 002
F2 Mapping Inhibited Restoral FJ 2002 FJNN002002 3 570 00 002
F3 Mapping Inhibited FT 2003 FTNN002003 1 570 00 003
F3 Mapping Inhibited Restoral FJ 2003 FJNN002003 3 570 00 003
F4 Mapping Inhibited FT 2004 FTNN002004 1 570 00 004
F4 Mapping Inhibited Restoral FJ 2004 FJNN002004 3 570 00 004
Fire Reset OR 0 ORNN000000 1 401 00 000
Fire System Overridden FS 0 FSNN000000 1 245 00 000
Fire System Override Restore FR 0 FRNN000000 3 245 00 000
Ground fault condition trouble YP Exp. ID YPNNXX0000 1 310 Exp. ID 000
Ground fault condition trouble
restore
YQ Exp. ID YQNNXX0000 3 310 Exp. ID 000
Initial power up RR 0 RRNN000000 1 305 00 000
Local programming aborted or
ended with errors
LU 0 LUNN000000 1 628 00 000
Local programming begin LB 0 LBNN000000 1 627 00 000
Local programming ended
normally
LS 0 LSNN000000 1 628 00 000
Network node trouble (panel
missing)
EM Panel ID EMNNNN0000 1 334 Panel ID 000
Network node trouble restore
(panel no longer missing)
EN Panel ID ENNNNN0000 3 334 Panel ID 000
OPG Inhibit Trouble FT Group # +
1000
FTNN001GGG 1 320 00 Group #
Table 12-2: Reporting Formats Table
SIA Reporting Format
Contact ID Reporting Format
SIA pi Modifier SIA IFP-2100/ECS
Event Description Module
ID # (If
Any)
SIA
Event
Codes
Parameter Fixed Length
Format NN -
panel ID
XX- SBUS ID
ZZZ- Zone #
PPPP- Point #
GGG- Group #
E- Emergency #
RRRR-Receiver #
Qualifier Event
Code
Group # Contact #

Table of Contents

Other manuals for Honeywell ECS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell ECS Series and is the answer not in the manual?

Honeywell ECS Series Specifications

General IconGeneral
BrandHoneywell
ModelECS Series
CategoryConference System
LanguageEnglish

Related product manuals