LS10143-001SK-E Reporting
12-4
SBUS expander trouble ET Exp. ID ETNNXX0000 1 333 Exp. ID 000
SBUS expander trouble restore ER Exp. ID ERNNXX0000 3 333 Exp. ID 000
SLC class A supervision trouble ET Exp. ID ETNNXX0000 1 331 Exp. ID 000
SLC class A supervision trouble
restore
ER Exp. ID ERNNXX0000 3 331 Exp. ID 000
SLC programming ended, system
active
TE 0 TENN000000 3 607 00 000
SLC programming started, sys-
tem shut down
TS 0 TSNN000000 1 607 00 000
SLC short circuit trouble ET Exp. ID ETNNXX0000 1 332 Exp. ID 000
SLC short circuit trouble restore ER Exp. ID ERNNXX0000 3 332 Exp. ID 000
Time changed event JT 0 JTNN000000 1 625 00 000
Unable to report to account
trouble
RT Receiver # RTNN00RRRR 1 354 00 Receiver
#
Unable to report to account
trouble restore
YK Receiver # YKNN00RRRR 3 354 00 Receiver
#
User access code changed JV 0 JVNN000000 1 602 00 000
User initiated manual dialer test RX 0 RXNN000000 1 601 00 000
Walk test begin TS 0 TSNN000000 1 607 00 000
Walk test end TE 0 TENN000000 3 607 00 000
Zone Events
Note: Zone events are reported only when “Report by Zone” is selected
Auxiliary power trouble FT 0000 FTNN000000 1 320 00 000
Auxiliary power trouble restore FJ 0000 FJNN000000 3 320 00 000
CO Detector Alarm GA Zone # GANN000ZZZ 1 162 00 Zone #
CO Detector Alarm Restore GH Zone # GHNN000ZZZ 3 162 00 Zone #
CO Detector Supervisory Alarm GS Zone # GSNN000ZZZ 1 200 00 Zone #
CO Detector Supervisory Alarm
Restore
GR Zone # GRNN000ZZZ 3 200 00 Zone #
CO Detector Trouble GT Zone # GTNN000ZZZ 1 373 00 Zone #
CO Detector Trouble Restore GJ Zone # GJNN000ZZZ 3 373 00 Zone #
Detector Alarm FA Zone # FANN000ZZZ 1 110 00 Zone #
Detector Alarm Restore FH Zone # FHNN000ZZZ 3 110 00 Zone #
Detector trouble FT Zone # FTNN000ZZZ 1 373 00 Zone #
Detector trouble restore FJ Zone # FJNN000ZZZ 3 373 00 Zone #
ECS Switch Trouble QT 0 QTNN000000 1 242 00 000
ECS Switch Trouble Restore QJ 0 QJNN000000 3 242 00 000
Table 12-2: Reporting Formats Table
SIA Reporting Format
Contact ID Reporting Format
SIA pi Modifier SIA IFP-2100/ECS
Event Description Module
ID # (If
Any)
SIA
Event
Codes
Parameter Fixed Length
Format NN -
panel ID
XX- SBUS ID
ZZZ- Zone #
PPPP- Point #
GGG- Group #
E- Emergency #
RRRR-Receiver #
Qualifier Event
Code
Group # Contact #