104 HF680 Series User Guide
GS1 Composite Codes
Linear codes are combined with a unique 2D composite component to form a new
class called GS1 Composite symbology. GS1 Composite symbologies allow for the
co-existence of symbologies already in use. Default = Off.
UPC/EAN Version
Scan the UPC/EAN Version On barcode to decode GS1 Composite symbols that
have a U.P.C. or an EAN linear component. (This does not affect GS1 Composite
symbols with a GS1-128 or GS1 linear component.) Default = UPC/EAN Version Off.
Note: If you scan coupons that have both UPC and GS1 Databarcodes, you may wish to
scan and output only the data from the GS1 Databarcode. See Coupon GS1 DataBar
Output (page 89) for further information.
GS1 Composite Code Message Length
Scan the barcodes below to change the message length. Refer to Message Length
Description (page 68) for additional information. Minimum and Maximum lengths
= 1-2435. Minimum Default = 1, Maximum Default = 2435.
On
* Off
UPC/EAN Version On
* UPC/EAN Version Off
Minimum Message Length

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell HF680 Series and is the answer not in the manual?

Honeywell HF680 Series Specifications

General IconGeneral
Image SensorCMOS
Symbol Contrast20% minimum reflectance difference
InterfaceUSB, RS-232, Keyboard Wedge
Operating Temperature32°F to 122°F (0°C to 50°C)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Humidity5% to 95% (non-condensing)
Light Levels0 to 100, 000 lux
Supported BarcodesUPC/EAN, Code 39, Code 128, QR Code, Data Matrix