HF680 Series User Guide 51
To remove this delay, scan the Intercharacter Delay barcode, then set the number
of delays to 0. Scan the Save barcode using the Programming Chart.
Note: Intercharacter delays are not supported in USB serial emulation.
User Specified Intercharacter Delay
An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be
placed after the transmission of a particular character of scanned data. Scan the
Delay Length barcode below, then scan the number of 5ms delays, and the Save
barcode using the Programming Chart.
Next, scan the Character to Trigger Delay barcode, then the 2-digit hex value for a
printable character to trigger the delay See ISO 2022/ISO 646 Character
Replacements on page 168..
To remove this delay, scan the Delay Length barcode, and set the number of delays
to 0. Scan the Save barcode using the Programming Chart.
Interfunction Delay
An interfunction delay of up to 5000 milliseconds (in 5ms increments) may be
placed between the transmission of each segment of the message string. Scan the
Interfunction Delay barcode below, then scan the number of 5ms delays, and the
Save barcode using the Programming Chart.
To remove this delay, scan the Interfunction Delay barcode, then set the number
of delays to 0. Scan the Save barcode using the Programming Chart.
Delay Length
Character to Trigger Delay
Interfunction Delays
Prefix Scanned Data Suffix
1 2345STX HT CR LF
Interfunction Delay

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell HF680 Series and is the answer not in the manual?

Honeywell HF680 Series Specifications

General IconGeneral
Image SensorCMOS
Symbol Contrast20% minimum reflectance difference
InterfaceUSB, RS-232, Keyboard Wedge
Operating Temperature32°F to 122°F (0°C to 50°C)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Humidity5% to 95% (non-condensing)
Light Levels0 to 100, 000 lux
Supported BarcodesUPC/EAN, Code 39, Code 128, QR Code, Data Matrix