50 HF680 Series User Guide
Function Code Transmit
When this selection is enabled and function codes are contained within the
scanned data, the scanner transmits the function code to the terminal. Charts of
these function codes are provided in the ASCII Conversion Chart (Code Page
1252). When the scanner is in keyboard wedge mode, the scan code is converted to
a key code before it is transmitted. Default = Enable.
Intercharacter, Interfunction, and Intermessage Delays
Some terminals drop information (characters) if data comes through too quickly.
Intercharacter, interfunction, and intermessage delays slow the transmission of
data, increasing data integrity.
Intercharacter Delay
An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be
placed between the transmission of each character of scanned data. Scan the
Intercharacter Delay barcode below, then scan the number of 5ms delays, and the
Save barcode using the Programming Chart.
Clear All Suffixes
* Enable
Disable
1 2345
Intercharacter Delay
Prefix Scanned Data Suffix
Intercharacter Delay

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell HF680 Series and is the answer not in the manual?

Honeywell HF680 Series Specifications

General IconGeneral
Image SensorCMOS
Symbol Contrast20% minimum reflectance difference
InterfaceUSB, RS-232, Keyboard Wedge
Operating Temperature32°F to 122°F (0°C to 50°C)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Humidity5% to 95% (non-condensing)
Light Levels0 to 100, 000 lux
Supported BarcodesUPC/EAN, Code 39, Code 128, QR Code, Data Matrix